| Output |
| DC Voltage |
52V |
| Rated Current |
2.5A |
| Current Range |
0 ~ 2.5A |
| Rated Power (Max) |
130W |
| Ripple & Noise (Max) |
150mVp-p |
| Voltage Adj. Range |
48 ~ 58V |
| Voltage Tolerance |
±1.0% |
| Line Regulation |
±0.5% |
| Load Regulation |
±0.5% |
| Setup, Rise, Hold Up Time |
2000ms, 70ms, 50ms/400VAC 2000ms, 70ms, 10ms/230VAC at Full Load |
| Input |
| Input Range |
200~240VAC |
| Frequency Range |
47 ~ 63Hz |
| Efficiency (Typ.) |
92% / 400V |
| AC Current |
2.3A/230VAC |
| Inrush Current (Max.) |
Cold Start 50A |
| Leakage Current |
<3.5mA / 530VAC |
| Protection |
| Overload |
105 ~ 130% Rated Output Power |
| Over Voltage |
57 ~ 63V |
| Over Temperature |
Shut Down O/P Voltage, Recovers Automatically After Temperature Goes Down |
| Function |
| DC OK Signal |
Relay Contact Rating(Max.) : 30V / 1A Resistive |
| Environment |
| Working Temp |
-25 ~ +70° (Refer to «Derating Curve») |
| Working Humidity |
20 ~ 90% RH Non-Condensing |
| Storage Temp., Humidity |
-40 ~ +85°, 10 ~ 95% RH |
| Temp. Coefficient |
±0.03% / °C (0 ~ 50°) °C |
| Vibration |
Component: 10 ~ 500Hz, 2G 10Min./1Cycle, 60Min. Each Along X, Y, Z Axes; Mounting Clip: Compliance To IEC60068-2-6 |
| Safety & EMC |
| Safety Standards |
UL508, EAC TP TC 004 approved, IEC60950-1 CB approved by SIQ, design refer to GL;(meet EN60204-1) |
| Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25°C/70% RH |
| EMC Emission |
Compliance to EN55011 (CISPR11), EN55032 (CISPR32), EN61204-3 Class B, EAC TP TC 020 |
| EMC Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020 |
| Other |
| Mounting |
DIN-Rail |
| Dimension |
125*65*92mm |
| Packing |
0.65Kg; 20pcs/14Kg/1.16CUFT |
| Guarantee |
| Product Guarantee |
1 Year Guarantee |
| MTBF |
268K hrs min. MIL-HDBK-217F (25°C) |